Sealing Machines: RHO I
Sealing of membranes to lid-rings
Technology:
- Pressure and heat are used to seal a membrane to a metal lid-ring.
- This makes for a hermetically tight and extremely reliable seal to allow sterilizeable closures.
- Modular system with turret principle
- The flexible modular system can be adapted to different
technological operations and output requirements
- The machine is available in versions with 1 or 2 lanes
for membrane coil.
- Optimized material utilisation of the membrane coil according to
the lid-ring size.(less scrap)
- Two membranes are cut out in a single stroke from the membrane coil.
- Both high output and high quality.
- In the first module the membranes are cut out and
transferred to the turret for pre-sealing.
- An hermetically tight and extremely reliable seal is created
by long sealing times.
- In the second module final sealing takes place with more than
0.5 seconds pure sealing time. More than 230° of the turret rotation
is available for sealing.
- In the third module the membranes are embossed.
- Prior to embossing, the stay-on tab is folded down
facing inwards and embossed at the same time.
- The sealing pressure and sealing temperature can be set individually
for each station.
- Each sealing tool is fitted with two automatically controlled heating systems
- one at the top and one at the bottom.
- If a sealing tool is too hot or not hot enough, this station is deactivated
during production and left empty. (No membrane is cut out and no lid-ring
is placed to this station)
- The transport of the membrane coil and scap skeleton
is carried out by servo drives.
- The machine is suitable for processing different sealable materials,
e.g. laminated aluminium-foil, plastic.
- In each working station in all modules, compound tool-sets
are used for a quick change of the dies:
- for membrane cutting,
- for pre-sealing,
- for final sealing,
- for embossing.
- An entire format change can be carried out in less than two hours.
- Very little maintenance is required thanks to the high-quality
components used.
Options:
- Flexer for the membrane coil
- Fragmentation of the scrap skeleton